Bangalore based distributor, applicator of BITUMAT Water Proofing Products such as APP modified bitumen membranes, Synroof Hi-build, Geo textiles, and various other Water Proofing Products.

Silicon Valley Waterproofing Company

Inquiry Basket (0)  

Roof Seal


Roof Seal
Click here for an enlarged view
We offer Bitumat Roof Seal, which is a pre-fabricated APP modified Bitumen membrane. This Roof Seal is designed for economical easy and applications. Roof Seal “P” is reinforced with a nonwoven polyester fabric, whereas Roof Seal “G” is reinforced with a glasfiber mat. The re-enforcement is impregnated and coated on both sides with polymer-modified bitumen.

Uses

Bitumat Roof Seal Membrane is ideal for a wide range of waterproofing applications including Roofs, Basements, Tunnels, Car Parks and Reservoirs.

Outstanding Features
  • Total impermeability

  • Good bond ability & seam integrity

  • Stability at high temperature

  • Good flexibility

  • Compatible with all normal roofing and building components

General Data

Nominal Roll Length : 10 Mtrs.
Nominal Roll Width : 1 M
Nominal Roll Thickness : 3,4,, MM
Re-enforcement : Nonwoven polyester/Glass fibre mat

Packaging
  • 3mm- 28 rolls / pallet

  • 4mm- 23 rolls / pallet

Finishes

Bitumat Roof Seal is available in two basic finishes:
  • Black smooth finish with polyethylene surfaces for covered applications.

  • Granule surfacing for exposed applications.

Quality Control

In addition to stringent regular tests by Bitumat laboratory, Independent laboratories test our products periodically.

Installation Tools Required

Gas torch, knife, trowel, measuring tape, marking string, gloves, etc

Application

Bitumat Roof Seal is installed by torch welding method, loose-laid or fully bonded to substrate. When loose-laid, only laps are bonded together.
Peripheries and protrusions are sealed according to specifications.

Coverage Rate (Approx)

(Rate may vary as per site requirement)

Flat areas : 1.15 M² /M² per layer with 10 cms. Side laps and 15cms. end Laps.

Torching Guidelines

The underside of the membrane should be torched just enough to superficially melt the bitumen. Excessive heating may damage the re-enforcement.
Overlaps should be re-heated from the top and resealed with a trowel to ensure seam integrity.

For details of installation methods and flashing requirements, consult the relevant Bitumat Systems and Installation Manual.





Content Copyright © Silicon Valley Waterproofing Company 2009, All Rights Reserved